Navigation


 

 

Poly Temp Online Catalog Ultra-Low Temperature and Cryogenic Storage Freezers

Accessories

Revco Freezer Accessories Directory
Introduction To Accessories
Validation Testing
Certificate of Calibration
Temperature Recorders
CO2/LN2 Back-Up Systems
Surge Suppressors
Alarm Delay Module
Deluxe Electronic Remote Alarm System
Digital Temperature Monitor
RS-232 Data Port
Cabinet Pass Thru Port
Stainless Steel Interior
Inside Delivery
Export Crating
LabCooler® Cryopreservaton Modules
Cryo Gloves

Introduction To Inventory Systems
Optional alarm and monitoring systems, temperature recorders, and LN2 /CO2 back-up systems offer an added measure of protection to match your storage application.

Some accessories are factory installed and must be specified with your original order. Other accessories are field installed, and may require the services of a factory authorized technician.

Accessories can improve freezer utility, convenience and safety. Occasionally, an accessory or option may affect the performance of your freezer.

Stainless steel interior surfaces, available as an option on some models may have slightly different thermal characteristics than original powder paint interiors
Alarms, monitors and back-up systems which are hard-wire connected to the freezer electrical system will have a slight affect on listed amperage ratings; in some cases, an accessory will require a power source with greater breaker capacity than listed in the freezer specification
For more information contact Revco or your sales representative

Serial number tags on all Revco freezers contain model numbers and voltage information needed for accurate selection of accessories ordered for field installation.

It is recommended that accessories be ordered when your freezer is ordered
Factory installed accessories allow proper set-up without power-down or emptying the freezer
Contact Revco for technical assistance with product selection, accessory configuration or application information

Validation Testing Program
Revco validation testing services in advance of shipment can accelerate in-house FDA Installation Qualification (IQ) and Operation Qualification (OQ) programs upon delivery. Revco factory validation services include documentation and performance reports, compressor and sub-system component specifications, microprocessor flow diagrams, software specifications and more. Validation must be requested when ordering; for details contact Revco.

Certification of Calibration
Revco control, alarm and temperature recording systems are systematically calibrated at the factory for accurate performance. An optional Certificate of Calibration to an NIST traceable instrument (National Institute of Standards and Technology, formerly National Bureau of Standards) includes a model number and serial number certificate, single point calibration. Multiple point calibration available. Calibration certificates must be requested when ordering; for details contact Revco.
Catalog No. 6916-2

     

Catalog No 6283-5

Temperature Recorders
All 6" (15.2 cm) circular chart, 7-day temperature recorders use pressure-sensitive chart paper; 1 box of 50 charts included. n No inking is required

Built-in, panel mounted recorders are factory installed (specify when ordering)
Free-standing recorders are customer installed

Temperature Recorder
6" chart, 7-day chart drive
-86°C and -40°C
Freezers
-140°C and -150°C
Freezers
Freezers Freezers Built-in, factory installed, specify when ordering Cat.No. 6183-6 Cat.No. 6183-5
Free-standing customer installed Cat. No. 6383-6 Cat. No. 6383-5
Chart paper, temperature range +50°C to -115°C Cat. No. 6185
Chart paper, temperature range 0°C to -200°C   Cat. No. 7289

Back-Up Systems
Back-up systems inject liquid CO2 or LN2 on demand when cabinet temperature warms to a pre-set level

Built-in back-up systems are available on Ultima II and Elite models only
All Ultima II, Elite and Value Series 3.1 cu.ft. (88 liters) -86°C models require a free-standing back-up system
Liquid flow is shut off automatically when the freezer door or lid is opened
Activation setpoints are adjustable in 1°C increments, to -75°C for CO2 and -150°C for LN2
The control module digital display shows actual temperature when button is pushed
An indicator light glows when activated
The system operates on a continually recharged battery, and includes all hardware except the supply cylinder

Description -86°C and -40°C
Freezers
-150°C and -140°C
Freezers
CO2 back-up system, built-in factory installed, specify when ordering Catalog No. 6594* n/a
LN2 back-up system, built-in factory installed, specify when ordering Catalog No. 6595* Catalog No. 6595
CO2 back-up system, free-standing, customer installed; specify when ordering Catalog No. 6593 n/a
LN2 back-up system, free-standing, customer installed; specify when ordering Catalog No. 6214 Catalog No. 6214

*Not available on 3.1 cu.ft.(88 liter) chest models.

Surge Suppressor
A built-in surge suppressor is standard on Ultima II Series models. A free-standing surge suppressor is available for Elite and Value Series models and requires field installation by a qualified electrician or factory authorized service center. Freezer model number and voltage must be specified when ordering.
Catalog No. 6402


Alarm Delay Module

Alarm Delay Module
The alarm delay eliminates nuisance alarms due to inter-mittent or transitory conditions such as lightning or brief power outages. The adjustable delay requires an alarm condition to exist continuously for a pre-determined time (adjustable) before a signal is released to a central alarm/moni-toring system or telephone dialer.

Adjustable delay from 0.5 to 32 minutes
Red alarm indicator light remains flashing after transient condition is corrected; requires manual reset
Signals chronic alarm conditions which may indicate impending component failure; allows time for inspection or corrective maintenance
Inserts variable time interval between detection of alarm condition and transmission of signal
Includes accurate digital timing circuit adjustable from 0.5, 1, 2, 4, 8, 18 or 32 minutes
Operates independent of line power; built-in battery and alarm test function uses 9V battery, customer supplied
Catalog No. 6903


Catalog No. 6224

Deluxe Electronic Remote Alarm
The Revco deluxe electronic remote alarm can be programmed to sound an alarm in the event of a temperature increase or power failure.

The alarm can dial up to 4 telephone numbers
Advises of an alarm condition across any telephone system which accepts pulse dialing
One system can monitor up to 4 individual freezers or up to 3 groups of freezers
Requires dedicated phone line
Catalog No. 6224


Catalog No. 6898

Digital Temperature Monitor
Simple, accurate and cost effective, the Revco digital tempera-ture and power moni-tor provides both alarm/monitoring and digital temperature display in a single, self-contained unit. Standard features include high alarm, alarm mute and chirp, audio delay timer, remote alarm contacts (SPDT), nicad battery back-up, and low voltage AC power supply, 120V, AC.

The monitor can be installed on or adjacent to any freezer
Activates an audible and visual warning in case of power failure or overtemperature condition
Choose from single probe digital models, or multiple probe microprocessor-based models
Temperature range is -100°C to +25°C
Probe size 1.25"L x 0.25" diameter (31.7 mm x 6 mm)

Digital Microprocessor-Based
Cat. No. 6898 6899 6900 6901 6902
Input Channels 1 1 2 3 4
Temperature Range -100°C to +25°C
Display & setpoint resolution 1°C 1°C 0.1°C 0.1°C 0.1°C
Temperature alarm high only high and low
LCD alphanumeric display numeric only 8-character, back-lit,
adjustable
Visual alarm red only green=normal;
red=deviation
Solid-state probe lead wire 8 foot
Teflon®
8 foot
24 gauge
20' Teflon®
color-coded
Relay delay n/a programmable,
0-30 minutes
Alarm/battery test switch n/a standard
Mounting method Velcro® bracket
Case dimensions 5"L x 4.5"W x 2"D
12.7 x 11.4 x 5cm
6.25"L x 3.25"W x 2"D
15.8 x 8.25 x 5cm

RS-232 Data Port and Software
For microprocessor-based Elite Series freezers only, standard on Ultima II models. Allows computer monitoring of freezer performance

Monitors freezer setpoint, high and low limit setpoints and power supply
Advises of temperature deviation, voltage boost, surge intercept, low alarm battery and clean filter functions
Automatic status reports are adjustable in increments of 5 seconds to 2 hours
Catalog No. 6405

Cabinet Pass-Thru Port
Each Revco ultra-low and cryogenic freezer includes a 1" diameter (2.54 cm) pass-thru port as standard equipment. Additional ports for probes, cables, leads or measuring instruments may be added. Additional ports are 1" diameter (2.54 cm) unless otherwise specified.
Catalog No. 6105

Stainless Steel Interior
An optional stainless steel interior may be substituted for the standard powder painted interior; specify when ordering.

Cabinet Size, cu.ft. liters   Cat. No.
3.1 (88 liters) chest   6121
6.8 (193 liters) chest   6122
10.3 (292 liters) chest   6123
13.7 (388 liters) chest   6124
17.1 (484 liters) chest   6125
20.5 (581 liters) chest   6126
13.4 (379 liters) upright   6179
17.2 (487 liters) upright   6180
20.2 (572 liters) upright   6181
24.4 (691 liters) upright   6645

Inside Delivery
Through a network of factory authorized service centers, Revco can arrange installation within your facility. Contact Revco if you have special delivery or instal-lation requirements. Prices are quoted by region.
Catalog No. 6095

Export Crating
Reinforced wooden crating may be desired for shipment to some international locations, depending on destination and mode of transport. Crating may be solid wood or frame only. Specify when ordering.

Description   Cat. No.
Solid wood   6099
Wood frame   6924


Catalog No. 6743


Catalog No. 6742

LabCooler® Cryopreservation Modules
Modules are useful in providing nominal control over pulldown during initial freeze cycles, and maintaining temperature stability of stored samples in vials during handling.

LabCooler™ and LabCooler™ Lite preservation modules are designed to freeze mammalian and insect cells with greater control over pulldown freezing prior to storage in an ultra-low freezer
Typical pulldown rates of 0.4°C to 0.6°C per minute improve cell viability from 80% to 90% 1
The LabCooler™ Lite benchtop cooler helps maintain frozen material temperature when used on the lab bench

LabCooler™ cryopreservation module; holds 32 standard vials
CatalogNo. 6742

LabCooler™ Lite cryopreservation module, holds 7 standard vials; includes a clear, interlocking top to allow viewing of contents.
Catalog No. 6743

LabCooler™ Lite benchtop cooler, holds 7 standard vials; includes a clear, interlocking top to allow viewing of contents.
Catalog No. 6745

1 Protocol Cells suspended in tissue-culture freezer medium (e.g. 95% FCS,5% DMSO cooled to -20°C) are transferred to cryovials which are then placed in the pre-chilled 4°C LabCooler™ cryopreservation module. The module is then placed in an ultra-low storage freezer for long term storage.


Catalog No. 4425

Cryo Gloves
Suitable for use with ultra-cold surfaces, Cryo Gloves protect hands and arm when inserting or removing inventory.

Layered material is specially selected for high insulation value with ample dexterity
Mid-arm style is available in sizes medium or large

Description   Cat. No.
Medium   4425
Large   4426
Back to Main ULT and Cryogenic Freezer Page
Back to top.
Poly Temp Main Navigation